Increase channels by adding additional block modules
YOKOGAWA proprietary block architecture [Patent technology]
-
Expand one, or multiple module at a time
-
Unique design houses modules in linked module bases
-
Module base ensures linkage (slide locks and mounting screws also available)
-
Modules can be inserted and removed from the front panel for easy maintenance
Names of data acquisition module parts
Comes standard with support for up to 100 ch of measurement (single-unit configuration)
Up to 10 I/O modules can be linked to a single data acquisition module (GM10)
Installs anywhere
For the desktop, DIN rails, or wall-mounting. No special attachments required.
Select from a wide range of I/O modules
Select modules according to your application. Noise-resistant, magnetic relay types also available. All modules have removable terminal blocks for easy wiring. The same modules used in the SMARTDAC+TM series.
Model
|
Name |
Measurement/Application |
Channels |
GX90XA-10-U2 |
Analog input module
|
DC voltage, DC current (with external shunt resistor connected), thermocouple, RTD, contact (solid state relay scanner type)
|
10
|
GX90XA-10-L1 |
DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (Low withstand voltage solid state relay scanner type)
|
10
|
GX90XA-10-T1 |
DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (electromagnetic relay scanner type)
|
10
|
GX90XA-10-C1 |
DC current (mA) (solid state relay scanner type)
|
10
|
GX90XA-10-V1 |
DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (Solid state relay scanner type)
|
10
|
GX90XA-04-H0 |
DC voltage, DC current (with external shunt resistor connected), thermocouple, RTD, contact (individual A/D type)
|
4
|
GX90XA-06-R1 |
4-wire RTD, 4-wire resistance(solid state relay scanner type)
|
6
|
GX90YA |
Analog output module
|
Current output (isolated between channels)
|
4
|
GX90XD |
Digital input module
|
Remote control input or operation recording
|
16
|
GX90YD |
Digital output module
|
Alarm output
|
6
|
GX90WD |
Digital input/output module
|
Remote control input or operation recording/alarm output
|
DI:8/DO:6
|
GX90XP |
Pulse input module
|
Pulse signal data acquisition, integral count
|
10
|
GX90UT |
PID control module
|
PID control (2 loop)
|
AI:2/AO:2 DI:8/DO:8
|
Analog input module scan interval and measurement type
Type |
Channels |
Scan interval (shortest)
|
Scanner |
TC |
RTD |
DCV |
DI |
mA |
Resistance |
Feature |
Universal (-U2) |
10 |
100ms |
SSR |
¡î |
¡î |
¡î |
¡î |
|
|
Universal |
Low withstand voltage relay (-L1) |
10 |
500ms |
SSR |
¡î |
|
¡î |
¡î |
|
|
Mid-price |
Electromagnetic relay (-T1) |
10 |
1s |
Relay |
¡î |
|
¡î |
¡î |
|
|
Noise-resistance |
DC current input (-C1) |
10 |
100ms |
SSR |
|
|
|
|
¡î |
|
mA only |
High withstand voltage (-V1) |
10 |
100ms |
SSR |
¡î |
|
¡î |
¡î |
|
|
High withstand voltage |
High speed universal (-H0) |
4 |
1ms |
— |
¡î |
¡î |
¡î |
¡î |
|
|
High speed measurement |
4-wire RTD (-R1) |
6 |
100ms |
SSR |
|
¡î |
|
|
|
¡î |
4-wireRTD |
Internal memory and max. I/O channels
Type |
Internal memory |
Max. input/output channels*
|
GM10-1 |
500 MB |
Single-unit configuration |
0 to 100 |
Multi-unit configuration |
0 to 100 |
GM10-2 |
1.2 GB |
Single-unit configuration |
0 to 100 |
Multi-unit configuration |
0 to 420 |
Actual values support high precision measurement
Input type |
Measuring accuracy*1 (typical value*2)
|
DCV |
20 mV |
¡¾(0.01% of reading + 5 ¥ìV) |
60 mV |
¡¾(0.01 % of reading +5 ¥ìV) |
6 V (1-5V) |
¡¾(0.01% of reading + 2 mV) |
TC*3
|
R, S |
¡¾1.1 ¡ÆC |
B |
¡¾1.5 ¡ÆC |
K (-200.0 to 1370.0¡ÆC) |
¡¾ (0.01% of rdg +0.2¡ÆC for 0.0 to 1370.0¡ÆC; ¡¾ (0.15% of rdg +0.2¡ÆC) for -200.0 to 0.0¡ÆC |
K (-200.0 to 500.0¡ÆC) |
¡¾ 0.2¡ÆC for 0.0 to 500.0¡ÆC; ¡¾ (0.15% of rdg +0.2¡ÆC) for -200.0 to 0.0¡ÆC |
J |
¡¾ 0.2¡ÆC for 0.0 to 1100.0¡ÆC; ¡¾ (0.10% of rdg + 0.2¡ÆC) for -200.0 to 0.0¡ÆC |
T |
¡¾ 0.2¡ÆC for 0.0 to 400.0¡ÆC; ¡¾ (0.10% of rdg + 0.2¡ÆC) for -200.0 to 0.0¡ÆC |
N |
¡¾ (0.01% of rdg + 0.2¡ÆC) for 0.0 to 1300.0¡ÆC; ¡¾ (0.22% of rdg + 0.2¡ÆC) for -200.0 to 0.0¡ÆC |
RTD |
Pt100 (-200.0 to 850.0¡ÆC) |
¡¾(0.02% of rdg + 0.2¡ÆC ) |
Pt100 (-150.00 to 150.00¡ÆC) |
¡¾(0.02% of rdg + 0.16¡ÆC ) |
*1 Applies to GX90XA-10-U2, A/D integration time 16.67 ms or more, General operating conditions: 23¡¾2 ¡ÆC, 55¡¾10% RH,
supply voltage 90-132, 180-264 V AC, power frequency within 50/60 Hz ¡¾1 %, warm-up of 30 minutes or more, no vibrations or other hindrances to performance.
*2 For the measuring accuracy (guaranteed), see the module¡¯s general specifications (GS 04L53B01-01EN).
*3 These values do not include the reference junction compensation accuracy.
Support measurement of up to 420 ch (actual input) by expanding channels across multiple units (multi-unit configuration)
Expand up to 420 ch by using the GX90EX expansion module. (GM10-2)
On the GM10-2 large capacity type, up to 1000 ch are available for recording when including MATH and communication channels. Connect units with LAN cables for dispersed installations.
You connect directly with a LAN cable without connecting through a hub or repeater.
* You can also connect a GX60 expansion unit.
Reduce wiring with distributed installation
When the data logger is installed offsite (away from the DUT), you can place the sub unit at the site and monitor data without the need for long-distance wiring of thermocouples and other sensors.