Á¦Ç°Á¤º¸

Modular GM10

Modular Data Logger

  • Á¦Á¶»ç:YOKOGAWA (JAPAN)
  • :* À¥ ±â¹ÝÀÇ ½Ç½Ã°£ µ¥ÀÌÅÍ ¸ð´ÏÅ͸µ
  • :* °£´ÜÇÑ Å»ÂøÀ¸·Î ¿øÇϴ ä³Î¼öÀÇ ÃøÁ¤°¡´É(ÃÖ´ë 420ä³Î)
  • :* ¸ð¹ÙÀÏ Á¢¼Ó°¡´É(ºí·çÅõ½º Åë½Å)

Increase channels by adding additional block modules

YOKOGAWA proprietary block architecture [Patent technology]

  • Expand one, or multiple module at a time
  • Unique design houses modules in linked module bases
  • Module base ensures linkage (slide locks and mounting screws also available)
  • Modules can be inserted and removed from the front panel for easy maintenance

YOKOGAWA proprietary block architecture

Names of data acquisition module parts

Names of data acquisition module parts

 

Comes standard with support for up to 100 ch of measurement (single-unit configuration)

Up to 10 I/O modules can be linked to a single data acquisition module (GM10)

Gm Image03

Installs anywhere

For the desktop, DIN rails, or wall-mounting. No special attachments required.

Gm Image04

Select from a wide range of I/O modules

Select modules according to your application. Noise-resistant, magnetic relay types also available. All modules have removable terminal blocks for easy wiring. The same modules used in the SMARTDAC+TM series.

Select from a wide range of I/O modules

 
 

Model

Name Measurement/Application Channels
GX90XA-10-U2

Analog input module

DC voltage, DC current (with external shunt resistor connected), thermocouple, RTD, contact (solid state relay scanner type)

10

GX90XA-10-L1

DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (Low withstand voltage solid state relay scanner type)

10

GX90XA-10-T1

DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (electromagnetic relay scanner type)

10

GX90XA-10-C1

DC current (mA) (solid state relay scanner type)

10

GX90XA-10-V1

DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (Solid state relay scanner type)

10

GX90XA-04-H0

DC voltage, DC current (with external shunt resistor connected), thermocouple, RTD, contact (individual A/D type)

4

GX90XA-06-R1

4-wire RTD, 4-wire resistance(solid state relay scanner type)

6

GX90YA

Analog output module

Current output (isolated between channels)

4

GX90XD

Digital input module

Remote control input or operation recording

16

GX90YD

Digital output module

Alarm output

6

GX90WD

Digital input/output module

Remote control input or operation recording/alarm output

DI:8/DO:6

GX90XP

Pulse input module

Pulse signal data acquisition, integral count

10

GX90UT

PID control module

PID control (2 loop)

AI:2/AO:2
DI:8/DO:8

Analog input module scan interval and measurement type

Type Channels Scan interval
(shortest)
Scanner TC RTD DCV DI mA Resistance Feature
Universal (-U2) 10 100ms SSR ¡î ¡î ¡î ¡î     Universal
Low withstand voltage relay (-L1) 10 500ms SSR ¡î   ¡î ¡î     Mid-price
Electromagnetic relay (-T1) 10 1s Relay ¡î   ¡î ¡î     Noise-resistance
DC current input (-C1) 10 100ms SSR         ¡î   mA only
High withstand voltage (-V1) 10 100ms SSR ¡î   ¡î ¡î     High withstand voltage
High speed universal (-H0) 4 1ms ¡î ¡î ¡î ¡î     High speed measurement
4-wire RTD (-R1) 6 100ms SSR   ¡î       ¡î 4-wireRTD

Internal memory and max. I/O channels

Type Internal memory Max. input/output channels*
GM10-1 500 MB Single-unit configuration 0 to 100
Multi-unit configuration 0 to 100
GM10-2 1.2 GB Single-unit configuration 0 to 100
Multi-unit configuration 0 to 420

Actual values support high precision measurement

Input type Measuring accuracy*1 (typical value*2)
DCV 20 mV ¡¾(0.01% of reading + 5 ¥ìV)
60 mV ¡¾(0.01 % of reading +5 ¥ìV)
6 V (1-5V) ¡¾(0.01% of reading + 2 mV)
TC*3 R, S ¡¾1.1 ¡ÆC
B ¡¾1.5 ¡ÆC
K (-200.0 to 1370.0¡ÆC) ¡¾ (0.01% of rdg +0.2¡ÆC for 0.0 to 1370.0¡ÆC; ¡¾ (0.15% of rdg +0.2¡ÆC) for -200.0 to 0.0¡ÆC
K (-200.0 to 500.0¡ÆC) ¡¾ 0.2¡ÆC for 0.0 to 500.0¡ÆC; ¡¾ (0.15% of rdg +0.2¡ÆC) for -200.0 to 0.0¡ÆC
J ¡¾ 0.2¡ÆC for 0.0 to 1100.0¡ÆC; ¡¾ (0.10% of rdg + 0.2¡ÆC) for -200.0 to 0.0¡ÆC
T ¡¾ 0.2¡ÆC for 0.0 to 400.0¡ÆC; ¡¾ (0.10% of rdg + 0.2¡ÆC) for -200.0 to 0.0¡ÆC
N ¡¾ (0.01% of rdg + 0.2¡ÆC) for 0.0 to 1300.0¡ÆC; ¡¾ (0.22% of rdg + 0.2¡ÆC) for -200.0 to 0.0¡ÆC
RTD Pt100 (-200.0 to 850.0¡ÆC) ¡¾(0.02% of rdg + 0.2¡ÆC )
Pt100 (-150.00 to 150.00¡ÆC) ¡¾(0.02% of rdg + 0.16¡ÆC )
*1 Applies to GX90XA-10-U2, A/D integration time 16.67 ms or more, General operating conditions: 23¡¾2 ¡ÆC, 55¡¾10% RH,
supply voltage 90-132, 180-264 V AC, power frequency within 50/60 Hz ¡¾1 %, warm-up of 30 minutes or more, no vibrations or other hindrances to performance.
*2 For the measuring accuracy (guaranteed), see the module¡¯s general specifications (GS 04L53B01-01EN).
*3 These values do not include the reference junction compensation accuracy.

Support measurement of up to 420 ch (actual input) by expanding channels across multiple units (multi-unit configuration)

Expand up to 420 ch by using the GX90EX expansion module. (GM10-2)
On the GM10-2 large capacity type, up to 1000 ch are available for recording when including MATH and communication channels. Connect units with LAN cables for dispersed installations.

Gm Image10

You connect directly with a LAN cable without connecting through a hub or repeater.
* You can also connect a GX60 expansion unit.

Reduce wiring with distributed installation

When the data logger is installed offsite (away from the DUT), you can place the sub unit at the site and monitor data without the need for long-distance wiring of thermocouples and other sensors.

Reduce wiring with distributed installation